The revolutionary IBUC G has advanced features and a Gallium Nitride (GaN) amplifier for increased efficiency.
IBUC G offers significant benefits:
- Low terminal cost
- Simple design and installation
- Superior RF performance
- Simplified 1+1 configuration
New interfaces connect you to extensive M&C facilities for network management or local access. This powerful new M&C enables:
- Trouble-free commissioning with easy, point-and-click installation/configuration
- Continuous verification of performance with time-stamped alarm history
- Simplified monitoring of terminal status
Details
- TCP/IP HTTP with embedded Web pages via RJ45 user interface connector
- SNMP
- TELNET through TCP/IP
- FSK through TX IFL cable
- RS232/485 serial port
- Hand-held terminal
Frequency range | |
---|---|
Band 1 Std Ku-Band RF IF |
14.00 to 14.50 GHz 950 to 1450 MHz |
Band 2 Full Ku-Band RF IF |
13.75 to 14.50 GHz 950 to 1700 MHz |
Input | |
VSWR / Impedance | 1.5:1 max / 50 Ohm |
Input Connector | Type N female (50 Ohm) |
Input Connector options | Type F (75 Ohm), TNC (50 Ohm) |
Input power detector | -55 to –20 dBm |
Gain | |
Small Signal Gain (L-band to RF) with attenuator set to 0 dB | |
150W / 200W | 83 dB min |
Attenuator range | 30 dB variable in 0.1 dB steps |
Gain flatness | |
Full band | 4 dB p-p max |
36 MHz | 1.5 dB p-p max |
1 MHz | 0.25 dB p-p |
Gain variation over temperature | |
Open loop | 3 dB p-p max |
With AGC | 1 dB p-p max |
RF Output | |
Interface | WR75 cover with groove |
VSWR | 1.3:1 max |
Output power | |
Psat (typ) 150W 200W |
+51.8 dBm +53 dBm |
Plin (min) 150W 200W |
+50 dBm +51 dBm |
Plin is the maximum linear power as defined by MIL STD 188-164B | |
Level stability with ALC | ±0.5 dB |
Output power detector range | Rated power to –20 dB |
Power reading accuracy | ±1.0 dB max. |
Spurious @ P | |
In Band | -65 dBc |
Out of Band | Complies with EN 301 428/430 and MIL-STD 188-164B |
Harmonics @ Plin | -60 dBc max. |
Output Noise Power Density | |
TX < -73 dBm/Hz RX < -145 dBm/Hz |
|
SSB Phase Noise | |
10 Hz External reference IBUC |
-115 dBc/Hz -50 dBc/Hz |
100 Hz External reference IBUC |
-140 dBc/Hz -75 dBc/Hz |
1 kHz External reference IBUC |
-150 dBc/Hz -85dBc/Hz |
10 kHz External reference IBUC |
-155 dBc/Hz -90 dBc/Hz |
100 kHz External reference IBUC |
n/a -95 dBc/Hz |
1 MHz External reference IBUC |
n/a -110 dBc/Hz |
External Reference (multiplexed on TX I FL) | |
Frequency | 10 MHz |
Level | -12 to +5 dBm |
Internal Reference - optional | |
Local Oscillator Frequency | |
Sense / Non-Inverting | |
Band 1 | 13050 MHz |
Band 2 | 12800 MHz |
IBUC Power Supply | |
Voltage AC | 200 to 240 VAC |
Power Consumption | |
at Plin 150W 200W |
1150 VA 1300 VA |
at Psat 150W 200W |
1300 VA 1500 VA |
Monitor and Control | |
Ethernet (HTTP , Telnet, SNMP ) via RJ45 connector, | |
RS232/485, Hand-held Terminal via MS-type connector, | |
FSK multiplexed on TX I FL. | |
Environmental | |
Operating temperature | -40oC to +55oC |
Relative humidity | 100% condensing |
Altitude | 10,000 ft., (3,000 m) ASL |
Mechanical | |
Size | 23 x 10 x 7.4 in. 584 x 254 x 188 mm |
Weight | 37 lbs, 17 kg |