- Description
- Technical Specifications
- Support Documents
Overview
The revolutionary IBUC has advanced features to take your network to new heights.
IBUC offers significant benefits:
- Low terminal cost
- Simple design and installation
- Superior RF performance
- Simplified 1+1 configuration
New interfaces connect you to extensive M&C facilities for network management or local access. This powerful new M&C enables:
- Trouble-free commissioning with easy, point-and-click installation/configuration
- Continuous verification of performance with time-stamped alarm history
- Simplified monitoring of terminal status The IBUC comes with a complete set of diagnostic
Details
- TCP/IP HTTP with embedded Web pages
- SNMP
- TELNET through TCP/IP
- FSK through TX IFL cable
- RS232/485 serial port
- Hand-held terminal
Frequency range | |
---|---|
Band 1 Std C-Band RF IF |
5850 to 6425 MHz 950 to 1525 MHz |
Band 2 Palapa/ST-1 RF IF |
6425 to 6725 MHz 975 to 1275 MHz |
Band 3 Insat RF IF |
6725 to 7025 MHz 1150 to 1450 MHz |
Band 4 Ext. C-Band RF IF |
5850 to 6650 MHz 950 to 1750 MHz |
Band 5 Full C-Band RF IF |
5850 to 6725 MHz 975 to 1850 MHz |
Input | |
VSWR / Impedance | 1.5:1 max / 50 Ohm |
Input Connector | Type N female (50 Ohm) |
Input Connector options | Type F (75 Ohm), TNC (50 Ohm) |
Input power detector | -55 to –20 dBm |
Gain | |
Small Signal Gain (L-band to RF) with attenuator set to 0 dB | |
100W | 81 dB min |
125W | 82 dB min |
150W | 83 dB min |
175W | 83 dB min |
200W | 84 dB min |
Attenuator range | 16 dB variable in 0.1 dB steps |
RF Output | |
Interface | CPR-137G |
VSWR | 1.3:1 max |
Rated output power (P1dB) | |
100 W | +50 dBm min |
125 W | +51 dBm min |
150 W | +51.8 dBm min |
175 W | +52.4 dBm min |
200 W | +53 dBm min |
Note: output power in bands 4 & 5 is reduced by 0.5 dB. | |
IMD3 | (2 carriers, 3 dB TOBO) -27 dBc max |
Level stability with ALC | +0.5 dB |
Output power detector range | Rated power to –20 dB |
Power reading accuracy | + 1.0 dB max. |
Harmonics | -50 dBc max. |
Output Noise Power Density | |
TX < -74 dBm/Hz RX < -145 dBm/Hz |
|
SSB Phase Noise | |
10 Hz External reference IBUC |
-115 dBc/Hz -54 dBc/Hz |
100 Hz External reference IBUC |
-140 dBc/Hz -79 dBc/Hz |
1 kHz External reference IBUC |
-150 dBc/Hz -89 dBc/Hz |
10 kHz External reference IBUC |
-155 dBc/Hz -94 dBc/Hz |
100 kHz External reference IBUC |
N/A -100 dBc/Hz |
1 MHz External reference IBUC |
N/A -110 dBc/Hz |
External Reference (multiplexed on TX I FL) | |
Frequency | 10 MHz |
Level | -12 to +5 dBm |
Internal Reference - optional | |
Local Oscillator Frequency | |
Sense / Inverting | |
Band 1 | 7375 MHz |
Band 2 | 7700 MHz |
Band 3 | 8175 MHz |
Band 4 | 7600 MHz |
Band 5 | 7700 MHz |
Monitor and Control | |
Ethernet (HTTP , Telnet, SNMP ), | |
RS232/485, Hand-held Terminal via MS-type connector, | |
FSK multiplexed on TX I FL. | |
Environmental | |
Operating temperature | -40oC to +55oC |
Relative humidity | 100% condensing |
Altitude | 10,000 ft., (3,000 m) ASL |
Mechanical | |
Size | 19.5x10x7.8 in. 495x254x198 mm |
Weight | 32 lbs, 14.5 kg DC powered 33 lbs, 15 kg AC powered |
(View our PDF Datasheet for more information) |