Overview
The 950-1450 MHz input is filtered and translated to the 250-750 MHz block output using dual conversion. The 250-750 MHz block output is AGCʼd to a composite output level that can be set for 0 to -10 dBm (AGC to ± 2 dB of setting) in 1 dB increments. The output translation can be adjusted by ± 10 MHz in 1 MHz increments. In Manual Gain, the gain can be set for +15 to +45 dB, ± 2 dB. Multifunction switches select the AGCʼd output level, MGC Gain and the translation frequency which appear on the LCD display and can be adjusted remotely. Front panel LEDs provide indication of DC power (green), PLL alarm (red), and remote operation (yellow). Connectors are Type F female for RF input and output. The unit is powered by a 100-240 ±10% VAC, 47-63 HZ input power supply and housed in a 1 3/4” X 19” X 16” rack mount chassis.