Back |
Super Extended C-Band Transceivers |
Part |
|
Number |
Description |
|
TX Frequencies: 5850 to 6725 MHz |
|
RX Frequencies: 3400 to 4200 MHz |
|
AnaSat Super
Extended
C-Band
VSAT Transceiver includes: 70 MHz IF input, output (type N for up
to 40W, CPR137 for higher powers) fixed gain, M&C, independent
TX/RX frequency and gain control, 65K LNC and 100 or 240 VAC
power. |
|
Note: One (1) LNC covers the entire Receive Frequency band. |
|
|
|
Single Enclosures Tranceivers: |
31207 |
AnaSat - 0 dBm SEC-Band Transceiver |
|
|
31208 |
AnaSat - 2W SEC-Band Transceiver |
|
|
31209 |
AnaSat - 5W SEC-Band Transceiver |
|
|
31210 |
AnaSat - 10W SEC-Band Transceiver |
|
|
TBD |
AnaSat - 10W SEC-Band Transceiver (without fan) |
|
|
31211 |
AnaSat - 20W SEC-Band Transceiver |
|
|
31212 |
AnaSat - 40W SEC-Band Transceiver |
|
|
|
Note: The following single enclosure Transceivers
are provide with CPR137G Waveguide RF Output Interface. |
|
|
31213 |
AnaSat - 50W SEC-Band Transceiver |
|
|
TBD |
AnaSat - 60W SEC-Band Transceiver |
|
|
TBD |
AnaSat - 70W SEC-Band Transceiver |
|
|
TBD |
AnaSat - 80W SEC-Band Transceiver |
|
|
TBD |
AnaSat - 100W SEC-Band Transceiver |
|
|
Back |
Super Extended C-Band Transceivers High Power |
Part |
|
Number |
Description |
|
High Power (Includes 0 dBm and HPA) |
|
(Output Power - SSPA=P1dB, TWTA=Psat) |
|
|
30792-150-S |
AnaSat - 150W SEC-Band Transceiver |
|
|
39792-200-S |
AnaSat - 200W SEC-Band Transceiver |
|
|
39792-300-S |
AnaSat - 300W SEC-Band Transceiver |
|
|
39792-400-S |
AnaSat - 400W SEC-Band Transceiver |
|
|
39792-500-S |
AnaSat - 500W SEC-Band Transceiver |
|
|
39792-600-S |
AnaSat - 600W SEC-Band Transceiver |
|
|
39792-700-S |
AnaSat - 700W SEC-Band Transceiver |
|
|
30792-170-S |
AnaSat -170W SEC-Band Transceiver TWTA (140W @ flange-One (1) year
warranty) |
|
|
30792-400-S |
AnaSat -400W SEC-Band Transceiver TWTA (350W @ flange-One (1) year
warranty) |
|
|
30792-700-S |
AnaSat -700W SEC-Band Transceiver TWTA (650W @ flange-One (1) year
warranty) |
|
|
Back |
Super
Extended C-Band 1+1 Protection Switch and Harness |
|
1+1 Protection Switch and Harness |
|
|
Select
Part Number Below |
AnaSat - PS 1+1 Redundant Protection Switch includes: Outdoor Control
/ Interface Box, CPR137 TX and CPR229 RX Waveguide Switches and Dummy
Loads (Pricing for Dummy Loads rated for more than 100W not included)
Redundant Cable Harness (Type N or waveguide) includes: All
Transceiver interconnect cables (length 3'), adapters and 3' low loss
coax (or flex waveguide), to connect to the Protection Switch, Waveguide
switches and LNCs (LNC and RX control cables are 10'). |
|
|
|
Protection Switch Serial Interface Options |
|
|
31087 |
Protection Switch for use with single enclosure Transceivers and RS232
remote interface. |
31088 |
Protection Switch for use with 0 dBm Transceivers and external HPAs
and RS232 remote interface. |
31258 |
Protection Switch for use with single enclosure Transceiver and RS485
remote interface. |
31259 |
Protection Switch for use with 0 dBm Transceivers and external HPAs
and RS485 remote interface. |
|
|
|
Windows / MS DOS M&C Software Disk
(also available on AnaCom's web site) |
|
|
Back |
Super Extended C-Band Cable Options |
Part |
|
Number |
Description |
|
|
|
Cable Options |
|
|
30720-010 |
Cable, DB-9 to ODU serial interface, standard 10' |
|
|
30720-025 |
Cable,DB-9 to ODU serial interface, length 25' |
|
|
30720-050 |
Cable,DB-9 to ODU serial interface, length 50' |
|
|
31199-100 |
Cable,RS232/485 Adapter to ODU serial interface, length 100' |
|
|
31199-150 |
Cable,RS232/485 Adapter to ODU serial interface, length 150' |
|
|
31199-200 |
Cable,RS232/485 Adapter to ODU serial interface, length 200' |
|
|
31198-003 |
Cable, LNC to Transceiver, length 3' |
|
|
31198-006 |
Cable, LNC to Transceiver, length 6' |
|
|
31198-010 |
Cable, LNC to Transceiver, length 10' |
|
|
31198-015 |
Cable, LNC to Transceiver, length 15' |
|
|
31198-020 |
Cable, LNC to Transceiver, length 20' |
|
|
31198-025 |
Cable, LNC to Transceiver, length 25' |
|
|
30933-010 |
Cable, RX switch to Transceiver, length 10', |
|
|
30933-015 |
Cable, RX switch to Transceiver, length 15', |
|
|
30933-020 |
Cable, RX switch to Transceiver, length 20', |
|
|
30933-025 |
Cable, RX switch to Transceiver, length 25', |
|
|
11706-003 |
Cable, Coax, low loss flexible, RF output, 3' |
|
|
11706-006 |
Cable, Coax, low loss flexible, RF output, 6' |
|
|
11706-010 |
Cable, Coax, low loss flexible, RF output, 10' |
|
|
11706-015 |
Cable, Coax, low loss flexible, RF output, 15' |
|
|
11706-020 |
Cable, Coax, low loss flexible, RF output, 20' |
|
|
11706-025 |
Cable, Coax, low loss flexible, RF output, 25' |
|
|
31198-005 |
Cable, Coax, RF low loss, Transceiver to SSPA, 5' |
|
|
30953-005 |
Cable, M&C, Transceiver to SSPA, 5' |
|
|
30952-005 |
Cable, M&C, Transceiver to Xicom TWTA, 5' |
|
|
10625-012 |
Power Cord, AC, 3 Pin, 12' (Used on older units) |
|
|
31185-015 |
Power Cord, AC, 4 Pin, 15' |
|
|
Back |
Super Extended C-Band LNCs |
Part |
|
Number |
Description |
|
Options and Accessories |
|
|
|
LNC Options sold with Transceiver: |
30570-65 |
LNC, 65K, Standard |
30570-45 |
LNC, 45K Option |
30570-35 |
LNC, 35K Option |
|
|
|
LNC Options sold without Transceiver: |
30570-65 |
LNC, 65K, Standard |
30570-45 |
LNC, 45K Option |
30570-35 |
LNC, 35K Option |
|
|
10917 |
TX Reject Filter |
|
|
30998 |
RF Port, LNC, Type N Connector (3.4 to 4.2 GHz) |
|
|
10988 |
Block Down Converter, Phased Locked, +/-25kHz, Input Freq. 3625
to 4200 MHz, Output Freq. 950 to 1525 MHz (Used for beacon tracking
and vidie montering). |
|
|
31052-001 |
Cable, LNC RF Port (Type N (M) to BDC (Type N (M), RG141 Semi-Rigid,
Length 14" |
|
|
31018 |
Terminal, Handheld (connects to Transciever 18 Pin M& C Connector) |
|
|
|
140 MHz IF Option |
|
|
|
External Reference, 10 MHz, SMA Connector
(Switchable between internal and external Ref.) |
|
|
|
48Vdc Line Voltage (0-5W Unit) |
|
|
|
48Vdc Line Voltage (10W Unit) |
|
|
|
48Vdc Line Voltage (20W Unit) |
|
|
|
48Vdc Line Voltage (40W Unit) |
|
|
10945-003 |
Flex Waveguide, CPR137, 3' |
|
|
10945-006 |
Flex Waveguide, CPR137, 6' |
|
|
10948 |
Adapter, CPR137 to Type N |
|
|
12307 |
Adapter, CPR229 (G) to Type N. |
|
|
|
Dummy Load, CPR137, 150W max. |
|
|
|
Dummy Load, CPR137, 250W max. |
|
|
|
Dummy Load, CPR137, 1kW max. |
|
|
10928 |
Waveguide Switch, CPR137G, Weatherized |
|
|
10927 |
Waveguide Switch, CPR229G, Weatherized |
|
|
10901 |
Fan Assembly (Fan, Cable Harness and Connector) |
|
|
10995 |
Impedance Matching Pad, 75 ohm to 50 ohm, Type N (F) the Type
N (M). Required for 75 ohm TX an RX IF Input Impedance. |
Back |
Super Extended C-Band Installation Kits |
Part |
|
Number |
Description |
|
|
|
Installation Kits |
|
|
12104 |
Installation Kit for 0dBm to 100W Single Enclosure Transceiver for
Prodelin and Channel Master offset antennas. Includes brackets
and mounting hardware to install on antenna feed support arm (3' flex
waveguide or low loss coax sold separately) |
|
|
31034 |
Universal Mounting Frame: Holds two (2)
EC-0 dBm to 100W or Ku-0 dBm to 40W Single Enclosure Transceivers
in a Redundant or Non-redundant configuration.
Note
-
The Frame is not designed for a specific antenna. Systems Integrators
determine how to install the Frame on their specific antenna. |
|
|
12114-001 |
Installation Kit, King Post/Pedestal Mount , 11.5” OD Maximum. Mounts
Redundant AnaCom Transceivers on the Prodelin 2.4m/3.8m and the Andrew
4.5m/4.6m/7.3m Antennas. |
|
|
12122 |
Installation Kit, Pedestal Mount. Mounts Redundant AnaCom Transceivers
on the Andrew 4.9m Antenna. |