C-Band Amplifier Redundancy
Kits - All of Advantech AMT's solid state amplifiers with microprocessor
controller (ARMA and AWMA Series) can be configured for redundant 1:1 or
1:2 operations. No external controller is required. For redundancy
operations, in addition to the amplifiers (operating and standby), a
special redundancy kit is required. The kit includes the waveguide
switches, terminations, RF splitter, waveguide arms and interconnecting
cables. A mounting frame is also required, please see the product list for
more details. Access for full remote monitoring and control of the system
is provided via the serial communication port.
Redundant Systems 1:1
For 1:1 operations, two redundant ready amplifiers (ARMA and AWMA Series),
one active and one standby, plus a 1:1 redundancy kit and a frame are
required. The standard 1:1 redundant SSPA systems are configured to
operate in the hot standby mode. The kit includes an input coaxial
splitter.
Redundant Systems 1:2
For 1:2 operations, three redundant ready amplifiers (ARMA and AWMA
Series), two active and one standby, and a 1:2 redundancy kit and a frame
are required. The standby amplifier will automatically replace a failed
amplifier. Switch-over will not occur to a defective or missing amplifier.
Contact:
Mike Termondt
Phone: 1.805.649.1384 - Fax: 1.805.500.4328 -
email