2009-140H 14.0 to 14.5 GHz Test Downconverter

 
The 2009-140H Test Downconverter converts a 14.0 - 14.5 GHz signal to 950 - 1450 MHz with a low side local oscillator (LO) (non-inverted spectrum). Featuring low phase noise and high stability, this unit is used to downconvert “clean” (having only this frequency) 14.0 - 14.5 GHz signals to 950 - 1450 MHz for test purposes. The 14.0 - 14.5 GHz input is mixed with a synthesized local oscillator (LO) signal to 950 - 1450 MHz. The mixer output is applied to the output amplifier providing a nominal gain of -20 dB. Connectors are 75 ohm female type-F for the 950 - 1450 MHz output and 50 ohm female type-N for the RF input. Front panel LEDs light when DC power is applied (green) and when a PLL alarm occurs (red). DC power is provided by the LNB voltage from the receiver under test or by an external 115 VAC, 60 Hz wall mount power supply (option -P). The 2009 can be mounted on an 1 3/4” X 19 “ rack mount panel (option -R).
 

2009-140H Test Downconverter Front

2009-140H Test Downconverter Rear Panel


2009-140H Test Downconverter Block Diagram

Equipment Specifications*
 

Input Characteristics
Impedance/RL
Frequency
Level, max
Input 1dB compression
50 ohms/10dB
14.0 - 14.5 GHz
0 to -15 dBm
+5 dBm
Output Characteristics  
Impedance/RL
Frequency
75 ohms/10dB
950 to 1450 MHz
Channel Characteristics  
Gain at band left
Spurious Response
Frequency Response
-20dB ±2dB
< -40dBC, 950-1450 MHz out
±2dB, 950-1450 MHz; ±0.5dB, any 10 MHz incr.
Synthesizer Characteristics  
Frequency Accuracy
Phase Noise (dBC/Hz)
±4ppm max
<= -70 @ 10kHz; <= -85 @ 100kHz; <= -95 @ 1MHz
Indicators
DC Power
Alarm
 
Green LED
Red LED
Other
RF IN Connectors
RF OUT Connectors
Size, Bench Top
Size, Rack Mount (-R)
Power
AC Power (-P)
Type N (female)
Type F (female)
4.7"W X 1.75"H X 6.5"D
19 inch standard chassis, 1.75"H X 7"D (optional)
+16 to +20 VDC, 400 ma on RF Out
120 ± 10% VAC, 60Hz, 15W max, wall mt PS
Models
2009-140H
2009-140HP
14.0 - 14.5 GHz in, 950-1450 MHz out, Uses Rcvr LNB Voltage
14.0 - 14.5 GHz in, 950-1450 MHz out, Wall Power Supply

*+10 to +40 degrees C; 2000 meters max elevation; 80% max humidity; Specifications subject to change without notice