1582-03, -04 Data Switches

 
The 1582-03 detects presence of data on a main (Data 1) and secondary (Data 2) data channel by detecting positive level transitions on both inputs. If no data is detected on the Data 1 channel for 1 to 9 minutes (adjustable in 1 minute increments), an alarm will occur causing the switch to transfer the Data 2 channel to the SELECTED DATA output. If the Data 2 channel also has an alarm, no switching will occur or switching can always be forced to the Data 2 channel. After switching to the Data 2 channel, when the Data 1 channel alarm clears the switch transfers data back to the Data 1 channel. Switching is accomplished using a relay so if power is removed from the 1582-03, there is signal continuity from the Data 1 channel to the SELECTED DATA output. Front panel LEDs indicate alarm conditions for the Data 1 and the Data 2 channels. The channels can be manually switched via a front panel switch. Dual switching power supplies provide redundant power to the 1582-03. The unit is housed in a 1 3/4”, rack mount chassis. The 1582-04 is a dual version of the 1582-03 and contains two independent switches in a 1 3/4” chassis.
1582-03, -04 Data Switches
 

Equipment Specifications*
 

Data Characteristics  
Input/Output
Data Rate
Connector
Pin Switched
Ground pin
RS232C
128 kB/s max
RJ45, female
2
5
Switch Characteristics  
Type
Isolation
Switch time
Contact Resistance
Configuration
Switch after alarm
Relay
>40dB
<=10 ms
<=10 ohms, <1 ohm typ
SPDT
Settable for 0-9 min in 1 min increments
Controls/Indicators
Manual Select
LEDS
Switches between manual or auto operation
CH1, CH2 on-line; MANUAL; ALARM CH1, CH2; REMOTE; PWR CH1, CH2
Other  
Mechanical
Power
19" standard chassis; 1.75"H X 12"D
90-260 VAC, 47-63Hz, 20W; Redundant switching

*+10 to +40 degrees C; Specifications subject to change without notice